Search

Home

Search

Search

  • ZL-30T 30 ton industrial FRP counter flow cooling tower - Maintenance Technician, 105.51 kW heat rejection, 23.4 m3/h water flow rate, 230 CMM airflow at 770 mm fan diameter, CE ISO certified for HVAC and process cooling applications.
    ZL-30T FRP counter flow cooling tower engineered for 30 ton (105.51 kW) heat rejection. 23.4 m3/h water flow, 0.75 kW fan motor, 230 CMM airflow. FRP shell, ABS fan. 5 deg C approach to wet-bulb at 27 deg C design condition. Specifications: 105.51 kW heat rejection at 30 refrigeration ton, FRP counter-flow shell with 5 deg C approach to wet-bulb 27 deg C design. 230 CMM airflow at 770 mm fan diameter, 0.75 kW motor at 380V 3-phase 50 Hz, 16 kPa head loss at 23.4 m3/h design flow. Dry weight 116 kg, operating weight 530 kg. CE ISO 9001:2015 certified, IP55 Class F insulation, FRP shell with ABS fan. Routine service: weekly water quality check, monthly float valve inspection, quarterly fill media inspection, annual fan motor bearing service. Compatible with standard water treatment chemicals. Spare parts inventory: fan motor 0.75 kW replacement, float valve assembly, fill media sections.
    Read More
  • ZL-25T 25 ton industrial FRP counter flow cooling tower - Maintenance Technician, 87.92 kW heat rejection, 19.51 m3/h water flow rate, 200 CMM airflow at 770 mm fan diameter, CE ISO certified for HVAC and process cooling applications.
    ZL-25T FRP counter flow cooling tower engineered for 25 ton (87.92 kW) heat rejection. 19.51 m3/h water flow, 0.75 kW fan motor, 200 CMM airflow. FRP shell, ABS fan. 5 deg C approach to wet-bulb at 27 deg C design condition. Specifications: 87.92 kW heat rejection at 25 refrigeration ton, FRP counter-flow shell with 5 deg C approach to wet-bulb 27 deg C design. 200 CMM airflow at 770 mm fan diameter, 0.75 kW motor at 380V 3-phase 50 Hz, 16 kPa head loss at 19.51 m3/h design flow. Dry weight 98 kg, operating weight 500 kg. CE ISO 9001:2015 certified, IP55 Class F insulation, FRP shell with ABS fan. Routine service: weekly water quality check, monthly float valve inspection, quarterly fill media inspection, annual fan motor bearing service. Compatible with standard water treatment chemicals. Spare parts inventory: fan motor 0.75 kW replacement, float valve assembly, fill media sections.
    Read More
  • ZL-15T 15 ton industrial FRP counter flow cooling tower - Maintenance Technician, 52.75 kW heat rejection, 11.7 m3/h water flow rate, 140 CMM airflow at 635 mm fan diameter, CE ISO certified for HVAC and process cooling applications.
    ZL-15T FRP counter flow cooling tower engineered for 15 ton (52.75 kW) heat rejection. 11.7 m3/h water flow, 0.37 kW fan motor, 140 CMM airflow. FRP shell, ABS fan. 5 deg C approach to wet-bulb at 27 deg C design condition. Specifications: 52.75 kW heat rejection at 15 refrigeration ton, FRP counter-flow shell with 5 deg C approach to wet-bulb 27 deg C design. 140 CMM airflow at 635 mm fan diameter, 0.37 kW motor at 380V 3-phase 50 Hz, 13 kPa head loss at 11.7 m3/h design flow. Dry weight 54 kg, operating weight 290 kg. CE ISO 9001:2015 certified, IP55 Class F insulation, FRP shell with ABS fan. Routine service: weekly water quality check, monthly float valve inspection, quarterly fill media inspection, annual fan motor bearing service. Compatible with standard water treatment chemicals. Spare parts inventory: fan motor 0.37 kW replacement, float valve assembly, fill media sections.
    Read More
  • ZL-20T low maintenance industrial cooling tower with 14 kPa head loss, easy service FRP shell, simple float valve and starter maintenance, water treatment compatibility for reduced downtime.
    ZL-20T low maintenance 20 ton cooling tower with 14 kPa head loss. Easy FRP shell service, simple float valve, weekly operator checks. Compatible with standard water treatment chemicals. Specifications: 70.4 kW heat rejection at 20 refrigeration ton, FRP counter-flow design with 5 deg C approach to wet-bulb 27 deg C. 165 CMM airflow, 0.55 kW fan motor at 380V 3-phase, 14 kPa head loss at 16 m3/h. Routine service: weekly water quality check, monthly float valve inspection, quarterly fill media inspection, annual fan motor bearing service. Compatible with standard water treatment chemicals.
    Read More
  • ZL-10T low maintenance industrial cooling tower with 13 kPa head loss, easy service FRP shell, simple float valve and starter maintenance, water treatment compatibility for reduced downtime.
    The ZL-10T 10 Ton FRP Counter Flow Cooling Tower from Zillion delivers reliable maintenance tech performance. Key specifications include: ZL-10T water chemistry: pH 6.5-9.0, Ca hardness
    Hot Tags : 10 ton counter flow
    Read More