  • ZL-30T 30 ton industrial FRP counter flow cooling tower - Data Center, 105.51 kW heat rejection, 23.4 m3/h water flow rate, 230 CMM airflow at 770 mm fan diameter, CE ISO certified for HVAC and process cooling applications.
    ZL-30T FRP counter flow cooling tower engineered for 30 ton (105.51 kW) heat rejection. 23.4 m3/h water flow, 0.75 kW fan motor, 230 CMM airflow. FRP shell, ABS fan. 5 deg C approach to wet-bulb at 27 deg C design condition. Specifications: 105.51 kW heat rejection at 30 refrigeration ton, FRP counter-flow shell with 5 deg C approach to wet-bulb 27 deg C design. 230 CMM airflow at 770 mm fan diameter, 0.75 kW motor at 380V 3-phase 50 Hz, 16 kPa head loss at 23.4 m3/h design flow. Dry weight 116 kg, operating weight 530 kg. CE ISO 9001:2015 certified, IP55 Class F insulation, FRP shell with ABS fan. Mission-critical reliability: 5 deg C wet-bulb approach at 27 deg C design condition for server room chiller integration. 230 CMM airflow, 0.75 kW fan motor at 380V 3-phase 50 Hz. CE ISO certified for mission-critical facilities with N+1 redundancy and 24/7 BMS monitoring per ASHRAE TC 9.9 standards. PUE impact: cooling tower efficiency directly affects overall data center energy consumption.
    Read More
  • ZL-25T 25 ton industrial FRP counter flow cooling tower - Data Center, 87.92 kW heat rejection, 19.51 m3/h water flow rate, 200 CMM airflow at 770 mm fan diameter, CE ISO certified for HVAC and process cooling applications.
    ZL-25T FRP counter flow cooling tower engineered for 25 ton (87.92 kW) heat rejection. 19.51 m3/h water flow, 0.75 kW fan motor, 200 CMM airflow. FRP shell, ABS fan. 5 deg C approach to wet-bulb at 27 deg C design condition. Specifications: 87.92 kW heat rejection at 25 refrigeration ton, FRP counter-flow shell with 5 deg C approach to wet-bulb 27 deg C design. 200 CMM airflow at 770 mm fan diameter, 0.75 kW motor at 380V 3-phase 50 Hz, 16 kPa head loss at 19.51 m3/h design flow. Dry weight 98 kg, operating weight 500 kg. CE ISO 9001:2015 certified, IP55 Class F insulation, FRP shell with ABS fan. Mission-critical reliability: 5 deg C wet-bulb approach at 27 deg C design condition for server room chiller integration. 200 CMM airflow, 0.75 kW fan motor at 380V 3-phase 50 Hz. CE ISO certified for mission-critical facilities with N+1 redundancy and 24/7 BMS monitoring per ASHRAE TC 9.9 standards. PUE impact: cooling tower efficiency directly affects overall data center energy consumption.
    Read More
  • ZL-15T 15 ton industrial FRP counter flow cooling tower - Data Center, 52.75 kW heat rejection, 11.7 m3/h water flow rate, 140 CMM airflow at 635 mm fan diameter, CE ISO certified for HVAC and process cooling applications.
    ZL-15T FRP counter flow cooling tower engineered for 15 ton (52.75 kW) heat rejection. 11.7 m3/h water flow, 0.37 kW fan motor, 140 CMM airflow. FRP shell, ABS fan. 5 deg C approach to wet-bulb at 27 deg C design condition. Specifications: 52.75 kW heat rejection at 15 refrigeration ton, FRP counter-flow shell with 5 deg C approach to wet-bulb 27 deg C design. 140 CMM airflow at 635 mm fan diameter, 0.37 kW motor at 380V 3-phase 50 Hz, 13 kPa head loss at 11.7 m3/h design flow. Dry weight 54 kg, operating weight 290 kg. CE ISO 9001:2015 certified, IP55 Class F insulation, FRP shell with ABS fan. Mission-critical reliability: 5 deg C wet-bulb approach at 27 deg C design condition for server room chiller integration. 140 CMM airflow, 0.37 kW fan motor at 380V 3-phase 50 Hz. CE ISO certified for mission-critical facilities with N+1 redundancy and 24/7 BMS monitoring per ASHRAE TC 9.9 standards. PUE impact: cooling tower efficiency directly affects overall data center energy consumption.
    Read More
  • ZL-20T data center cooling tower with 5 deg C wet-bulb approach at design WB 27 deg C, 70 kW heat duty for server room HVAC chillers, FRP counter flow design, CE ISO certified for mission critical facilities.
    ZL-20T data center cooling tower with 5 deg C wet-bulb approach at design WB 27 deg C. 70 kW heat duty for server room chiller integration, FRP counter flow. Specifications: 70.4 kW heat rejection at 20 refrigeration ton, FRP counter-flow shell with 5 deg C wet-bulb approach at 27 deg C design condition for server room chiller integration. 165 CMM airflow, 0.55 kW fan motor at 380V 3-phase 50 Hz. CE ISO certified for mission-critical facilities with N+1 redundancy and 24/7 BMS monitoring per ASHRAE TC 9.9.
    Read More
  • ZL-10T data center cooling tower with 5 deg C wet-bulb approach at design WB 27 deg C, 76 kW heat duty for server room HVAC chillers, FRP counter flow design, CE ISO certified for mission critical facilities.
    The ZL-10T 10 Ton FRP Counter Flow Cooling Tower from Zillion delivers reliable data center performance. Key specifications include: ZL-10T cooling capacity: 35.2 kW for 25-28 kW IT load PUE 1.38 with water-cooled chiller pairing (VFD: 1.15-1.25) WUE: 10.4 L/kWh at moderate climate (8,760 hours/year) Tier III N+1 redundancy with two ZL-10T towers 60 dB rating acceptable for indoor edge data center Vibration isolation pads reduce structure-borne noise 5,100 m3/h air supply requirement for indoor installation Compatible with warm-water direct-to-chip cooling (40C supply) Designed for industrial-grade data center applications, the ZL-10T combines proven FRP counter flow technology with precision-engineered components for 15-20 year service life. CE / ISO 9001:2015 certified. Contact Leika at Leika@gdzillion.cn for quotation.