Products

Home Refrigeration Machinery Cooling Tower Series

ZL-125T 125 Ton Industrial FRP Counter Flow Cooling Tower - Sustainability ESG

ZL-125T 125 ton industrial FRP counter flow cooling tower, 439.52 kW heat rejection, 97.5 m3/h water flow, 830 CMM airflow at 1450 mm fan, CE ISO certified for HVAC and process cooling applications.

ZL-125T 125 Ton Industrial FRP Counter Flow Cooling Tower - Sustainability ESG

ZL-125T FRP counter flow cooling tower engineered for 125 ton (439.52 kW) heat rejection. 97.5 m3/h water flow, 2.2 kW fan motor, 830 CMM airflow. FRP shell, ABS fan. 5 deg C approach to wet-bulb at 27 deg C design condition. Specifications: 439.52 kW heat rejection at 125 refrigeration ton, FRP counter-flow shell with 5 deg C approach to wet-bulb 27 deg C design. 830 CMM airflow at 1450 mm fan diameter, 2.2 kW motor at 380V 3-phase 50 Hz, 23 kPa head loss at 97.5 m3/h design flow. Dry weight 540 kg, operating weight 1640 kg. CE ISO 9001:2015 certified, IP55 Class F insulation, FRP shell with ABS fan.

  • Brand:

    Dongguan Zillion
  • ItemNO:

    ZL-125T
  • Order(MOQ):

    1
  • Payment:

    T/T,L/C,Western Union
  • MarketPrice:

    $2976
  • price:

    $2400/Set/Sets
  • PriceRange:

    11 - 20/$2208
  • PriceRange:

    6 - 10/$2280
  • PriceRange:

    2 - 5/$2352
  • PriceRange:

    1 - 1/$2400
  • ProductOrigin:

    China
  • Color:

    Blue + Gray (customizable)
  • ShippingPort:

    Shenzhen / Guangzhou
  • LeadTime:

    7-15 days (small batch) / 20-30 days (bu
  • Weight:

    540
  • Name:

    ZL-125T
  • Item NO:

    Inlet 2900x2900mm
  • Size:

    Overall 2900x2900x2570mm

125 Ton Cooling Tower Technical Specifications and Application Details

The ZL-125T FRP counter flow cooling tower delivers 439.52 kW heat rejection at 125 refrigeration tons with 97.5 m3/h water flow rate. The following sections detail engineering specifications, operational considerations, and application-specific integration guidance for the ZL-125T.

Water Conservation: Drift Loss Reduction for Large-Scale ZL-125T

The ZL-125T cooling tower achieves 0.005 percent drift loss (less than 10 L/h at design flow), compared to 0.02 percent drift loss for conventional towers. For an installation operating at 97.5 m3/h circulation rate, this represents a savings of 12 L/h or approximately 105 m3 per year. Over the 15-year service life of the ZL-125T, total water savings versus a conventional tower equals approximately 1,575 m3. Combined with proper water treatment and cycles of concentration management, the ZL-125T enables water consumption reductions of 30 percent versus older tower installations.

Energy Efficiency: 2.2 kW Fan Motor Performance at Industrial Scale

The ZL-125T's 2.2 kW fan motor is sized to provide 439.52 kW heat rejection at design conditions, achieving a motor-to-heat-duty efficiency ratio of 199. For variable-speed operation, the ZL-125T's motor can be controlled by VFD to reduce airflow during low-load periods: at 50 percent airflow, fan power consumption drops to 12.5 percent of design (cube law), enabling 80 percent plus energy savings during shoulder seasons. The annual energy consumption is approximately 9636 kWh assuming 50 percent average load factor.

FRP Material Sustainability and Recyclability for ZL-125T

The ZL-125T's FRP shell provides 15-20 year service life with minimal environmental impact during operation. At end-of-life, the FRP shell can be mechanically crushed and used as filler material in concrete or asphalt applications, providing 30-50 percent recycled content in new construction materials. The PVC fill media is recyclable through specialized plastic recyclers, with 80 percent material recovery possible. The 2.2 kW fan motor contains approximately 25 kg of copper windings, which are 95 percent recyclable.

Carbon Footprint Comparison: ZL-125T Versus Alternative Technologies

The ZL-125T cooling tower's lifecycle carbon footprint compares favorably against alternative cooling technologies. Manufacturing carbon footprint: approximately 400 kg CO2e per tower. Operational carbon footprint: 72270 kg CO2e over 15 years. Total: approximately 72670 kg CO2e per ZL-125T over service life. Compared to air-cooled chillers, the ZL-125T saves 30-40 percent of operational carbon by enabling chiller efficiency improvements.

ESG Reporting Metrics for ZL-125T Deployment at Industrial Scale

For corporate ESG reporting at industrial deployment scale, the ZL-125T contributes measurable improvements across GRI Standards, SASB, CDP Climate, and TCFD reporting frameworks. ZILLION provides product-level LCA data for the ZL-125T including carbon footprint per unit, water consumption per year, and end-of-life recyclability percentages. For multi-site industrial deployments, aggregate ESG impact is reported across all ZL-125T installations.

Water-Energy Nexus Optimization with ZL-125T at Industrial Scale

At industrial scale, the ZL-125T enables optimization of the water-energy nexus in commercial and industrial facilities. By providing 32 deg C leaving water at design conditions, the tower enables water-cooled chiller operation at higher efficiency than air-cooled alternatives, reducing electricity consumption by 30-40 percent. For water-stressed regions, the ZL-125T can be paired with dry air-cooled pre-coolers to reduce water consumption by 50 percent while maintaining 80 percent of cooling performance.

Send A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related Products

ZL-CT40 Industrial Round Cooling Tower 40T FRP
Industrial Fiberglass FRP GRP Counter Flow Cooling Tower Price Round FRP Cooling Tower 40T

Quick Specs: ZL-CT40 industrial round cooling tower with 40-ton cooling capacity, FRP material, counter-flow design, 1.5kW fan, CE certified. Best for industrial chiller systems and mid-scale manufacturing. The water cooling tower is a device used for cooling circulating water. By exchanging heat between hot water and air, the water temperature is reduced, thus realizing the repeated use of circulating water. Water cooling towers are widely used in industrial production, air conditioning systems and other fields, and are of great significance for saving water resources and reducing energy consumption.  

ZL-CT60 Round Shape Water Cooling Tower 60T
60T Round Shape Water Cooling Tower for Chiller Counter Flow Circular Cooling Tower Industrial Cooling System FRP Competitive Price

Quick Specs: ZL-CT60 round shape water cooling tower with 60-ton capacity, counter-flow design, FRP material, 1.5kW fan, CE certified. Best for industrial chiller systems and large-scale cooling. A water cooling tower is a device used for cooling industrial water or other liquids. Its main function is to cool down hot water through heat exchange between hot water and air so that the cooled water can be recycled.      

ZL-CT100 FRP Round Cooling Tower 100T
FRP Material 100 Ton Round Cooling Tower Price

Quick Specs: ZL-CT100 FRP round cooling tower with 100-ton cooling capacity, FRP material, 2.2kW fan, CE certified. Best for large-scale industrial cooling and high-capacity chiller systems. The counterflow cooling tower is a common type of cooling tower. It sprays hot water from top to bottom and air flows from bottom to top, enabling hot water and air to exchange heat in the packing, thereby reducing the water temperature. The counterflow cooling tower has the advantages of high cooling efficiency, compact structure and small floor area, and is widely used in industrial production, air conditioning and refrigeration and other fields.    

ZL-CT Square Drop Counter-Flow Cooling Tower FRP
Square Cooling Tower for Water Cooling: High - temperature Square Drop Counter - flow FRP and Open Cooling Towers

Quick Specs: ZL-CT square drop counter-flow cooling tower with FRP material, multiple capacity options, CE certified. Best for high-temperature industrial water cooling and open cooling tower applications. The square cooling tower has the advantages of small floor area, beautiful appearance, and convenient installation. It is widely used in fields such as air conditioning and refrigeration and industrial cooling, providing effective cooling guarantee for the normal operation of various equipments.      

ZL-CT Industrial Cooling Tower Multiple Types High Efficiency
Factory Direct High-Efficiency Industrial Cooling Tower Multiple Types Available

Quick Specs: ZL-CT factory-direct industrial cooling tower with multiple types and capacities, high-efficiency design, CE certified. Best for industrial cooling applications and large-scale manufacturing. A cooling tower dissipates heat from industrial or air - conditioning systems. Its working principle involves spraying hot water onto packing to form a water film, while air flow carries away heat from the water to lower its temperature. The cooled water is recyclable, saving water resources and reducing costs.​ There are various types, such as open and closed cooling towers. Open ones contact outside air directly, making water prone to contamination but with lower costs. Closed ones have water circulating in sealed pipes, ensuring cleaner water but usually at a higher price.​ Cooling towers play a key role in fields like power plants, chemical plants, and data centers, helping maintain system operation and improve energy utilization efficiency.​  

ZL-10T 10 ton industrial cooling tower at competitive factory direct price EXW Dongguan, FOB Shenzhen and CIF terms available, T/T L/C payment accepted, bulk discount for volume procurement, CE ISO certified.
ZL-10T 10 Ton Industrial FRP Counter Flow Cooling Tower - CFO Procurement

The ZL-10T 10 Ton FRP Counter Flow Cooling Tower from Zillion delivers reliable cfo procurement performance. Key specifications include: ZL-10T 10 ton FRP counter flow cooling tower at USD 850 EXW 5-year TCO: USD 850 capex + USD 2,971/year opex Volume discounts: USD 765 (10+), USD 680 (50+), USD 595 (100+) Payment terms: T/T 30/70, L/C, Western Union, Alibaba Trade Assurance 18-month payback vs USD 4,500 air-cooled alternative Annual spare parts budget: USD 180 EXW Dongguan, lead time 7-15 days CE certified for global deployment Designed for industrial-grade cfo procurement applications, the ZL-10T combines proven FRP counter flow technology with precision-engineered components for 15-20 year service life. CE / ISO 9001:2015 certified. Contact Leika at Leika@gdzillion.cn for quotation.

ZL-10T low maintenance industrial cooling tower with 13 kPa head loss, easy service FRP shell, simple float valve and starter maintenance, water treatment compatibility for reduced downtime.
ZL-10T 10 Ton Industrial FRP Counter Flow Cooling Tower - Maintenance Technician

The ZL-10T 10 Ton FRP Counter Flow Cooling Tower from Zillion delivers reliable maintenance tech performance. Key specifications include: ZL-10T water chemistry: pH 6.5-9.0, Ca hardness

ZL-10T HVAC cooling tower for industrial EPC projects, 380V 3-phase 50Hz motor, IP55 Class F insulation, CE ISO certified, FRP counter flow design suitable for HVAC and process integration.
ZL-10T 10 Ton Industrial FRP Counter Flow Cooling Tower - HVAC EPC Contractor

The ZL-10T 10 Ton FRP Counter Flow Cooling Tower from Zillion delivers reliable epc contractor performance. Key specifications include: ZL-10T concrete pad: 600x600x150 mm C25/30 mix Wind load rating: 0.5 kPa for open terrain Piping connections: DN50 inlet/outlet, DN15 makeup, DN50 overflow 46 kg dry weight enables two-person ground-level installation Rooftop lift: portable gantry rated 250 kg Electrical: 380V 3-phase 50Hz, 1.2-1.5 A FLA VFD option for 30-60 Hz variable-speed operation 12-point pre-commissioning checklist Designed for industrial-grade epc contractor applications, the ZL-10T combines proven FRP counter flow technology with precision-engineered components for 15-20 year service life. CE / ISO 9001:2015 certified. Contact Leika at Leika@gdzillion.cn for quotation.

If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.