Products

Home Refrigeration Machinery Cooling Tower Series

100 Ton Industrial FRP Counter Flow Cooling Tower - Sustainability ESG

Water saving evaporative cooling tower with low drift loss for ESG compliance and LEED documentation projects

100 Ton Industrial FRP Counter Flow Cooling Tower - Sustainability ESG

Overview

100 Ton Industrial FRP counter flow cooling tower delivers reliable heat rejection for industrial process cooling applications. ZLILLION engineered this 100 ton counter flow cooling tower with CE ISO 9001:2015 certification and quality construction for long service life.

Key Specifications

  • Cooling capacity: 351.62 kW (100 refrigeration ton)
  • Water flow rate: 78.1 m3/h design flow
  • Heat rejection: 5 deg C approach to wet-bulb at 27 deg C design
  • Fan airflow: 700 CMM at 1450 mm fan diameter
  • Motor power: 2.2 kW at 380V 3-phase 50 Hz
  • Head loss: 21 kPa at design flow
  • Dry weight: 500 kg, operating weight: 1690 kg
  • Overall dimensions: H2570 x Dia2900 mm

Design Features

  • FRP counter-flow shell for corrosion resistance and long life
  • ABS fan blade for low maintenance and quiet operation
  • IP55 Class F insulation for harsh industrial environments
  • Counter flow design for maximum heat transfer efficiency
  • Drift eliminator reduces water loss to 0.01 percent of circulation

Applications

Water saving low drift loss design with ESG and LEED documentation compliance. Reduces water consumption 30 percent versus standard cooling towers.

Contact ZILLION Today

Get a quote for the ZL-100T cooling tower from ZILLION factory direct. Contact our engineering team for factory pricing, technical specifications, and bulk discount tiers for your project requirements.

  • Brand:

    Dongguan Zillion
  • ItemNO:

    ZL-100T
  • Order(MOQ):

    1
  • Payment:

    T/T,L/C,Western Union
  • MarketPrice:

    $2294
  • price:

    $1850/Set/Sets
  • PriceRange:

    11 - 20/$1702
  • PriceRange:

    6 - 10/$1757.5
  • PriceRange:

    2 - 5/$1813
  • PriceRange:

    1 - 1/$1850
  • ProductOrigin:

    China
  • Color:

    Blue + Gray (customizable)
  • ShippingPort:

    Shenzhen / Guangzhou
  • LeadTime:

    20-30 days
  • Weight:

    500
  • Name:

    100T cooling tower
  • Size:

    H2570 x Dia2900mm

100 Ton Cooling Tower Technical Specifications and Application Details

The ZL-100T FRP counter flow cooling tower delivers 351.62 kW heat rejection at 100 refrigeration tons with 78.1 m3/h water flow rate. The following sections detail engineering specifications, operational considerations, and application-specific integration guidance for the ZL-100T.

Water Conservation: Drift Loss Reduction for Large-Scale ZL-100T

The ZL-100T cooling tower achieves 0.005 percent drift loss (less than 10 L/h at design flow), compared to 0.02 percent drift loss for conventional towers. For an installation operating at 78.1 m3/h circulation rate, this represents a savings of 12 L/h or approximately 105 m3 per year. Over the 15-year service life of the ZL-100T, total water savings versus a conventional tower equals approximately 1,575 m3. Combined with proper water treatment and cycles of concentration management, the ZL-100T enables water consumption reductions of 30 percent versus older tower installations.

Energy Efficiency: 2.2 kW Fan Motor Performance at Industrial Scale

The ZL-100T's 2.2 kW fan motor is sized to provide 351.62 kW heat rejection at design conditions, achieving a motor-to-heat-duty efficiency ratio of 159. For variable-speed operation, the ZL-100T's motor can be controlled by VFD to reduce airflow during low-load periods: at 50 percent airflow, fan power consumption drops to 12.5 percent of design (cube law), enabling 80 percent plus energy savings during shoulder seasons. The annual energy consumption is approximately 9636 kWh assuming 50 percent average load factor.

FRP Material Sustainability and Recyclability for ZL-100T

The ZL-100T's FRP shell provides 15-20 year service life with minimal environmental impact during operation. At end-of-life, the FRP shell can be mechanically crushed and used as filler material in concrete or asphalt applications, providing 30-50 percent recycled content in new construction materials. The PVC fill media is recyclable through specialized plastic recyclers, with 80 percent material recovery possible. The 2.2 kW fan motor contains approximately 25 kg of copper windings, which are 95 percent recyclable.

Carbon Footprint Comparison: ZL-100T Versus Alternative Technologies

The ZL-100T cooling tower's lifecycle carbon footprint compares favorably against alternative cooling technologies. Manufacturing carbon footprint: approximately 400 kg CO2e per tower. Operational carbon footprint: 72270 kg CO2e over 15 years. Total: approximately 72670 kg CO2e per ZL-100T over service life. Compared to air-cooled chillers, the ZL-100T saves 30-40 percent of operational carbon by enabling chiller efficiency improvements.

ESG Reporting Metrics for ZL-100T Deployment at Industrial Scale

For corporate ESG reporting at industrial deployment scale, the ZL-100T contributes measurable improvements across GRI Standards, SASB, CDP Climate, and TCFD reporting frameworks. ZILLION provides product-level LCA data for the ZL-100T including carbon footprint per unit, water consumption per year, and end-of-life recyclability percentages. For multi-site industrial deployments, aggregate ESG impact is reported across all ZL-100T installations.

Water-Energy Nexus Optimization with ZL-100T at Industrial Scale

At industrial scale, the ZL-100T enables optimization of the water-energy nexus in commercial and industrial facilities. By providing 32 deg C leaving water at design conditions, the tower enables water-cooled chiller operation at higher efficiency than air-cooled alternatives, reducing electricity consumption by 30-40 percent. For water-stressed regions, the ZL-100T can be paired with dry air-cooled pre-coolers to reduce water consumption by 50 percent while maintaining 80 percent of cooling performance.

Send A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related Products

ZL-CT40 Industrial Round Cooling Tower 40T FRP
Industrial Fiberglass FRP GRP Counter Flow Cooling Tower Price Round FRP Cooling Tower 40T

Quick Specs: ZL-CT40 industrial round cooling tower with 40-ton cooling capacity, FRP material, counter-flow design, 1.5kW fan, CE certified. Best for industrial chiller systems and mid-scale manufacturing. The water cooling tower is a device used for cooling circulating water. By exchanging heat between hot water and air, the water temperature is reduced, thus realizing the repeated use of circulating water. Water cooling towers are widely used in industrial production, air conditioning systems and other fields, and are of great significance for saving water resources and reducing energy consumption.  

ZL-CT60 Round Shape Water Cooling Tower 60T
60T Round Shape Water Cooling Tower for Chiller Counter Flow Circular Cooling Tower Industrial Cooling System FRP Competitive Price

Quick Specs: ZL-CT60 round shape water cooling tower with 60-ton capacity, counter-flow design, FRP material, 1.5kW fan, CE certified. Best for industrial chiller systems and large-scale cooling. A water cooling tower is a device used for cooling industrial water or other liquids. Its main function is to cool down hot water through heat exchange between hot water and air so that the cooled water can be recycled.      

ZL-CT100 FRP Round Cooling Tower 100T
FRP Material 100 Ton Round Cooling Tower Price

Quick Specs: ZL-CT100 FRP round cooling tower with 100-ton cooling capacity, FRP material, 2.2kW fan, CE certified. Best for large-scale industrial cooling and high-capacity chiller systems. The counterflow cooling tower is a common type of cooling tower. It sprays hot water from top to bottom and air flows from bottom to top, enabling hot water and air to exchange heat in the packing, thereby reducing the water temperature. The counterflow cooling tower has the advantages of high cooling efficiency, compact structure and small floor area, and is widely used in industrial production, air conditioning and refrigeration and other fields.    

ZL-CT Square Drop Counter-Flow Cooling Tower FRP
Square Cooling Tower for Water Cooling: High - temperature Square Drop Counter - flow FRP and Open Cooling Towers

Quick Specs: ZL-CT square drop counter-flow cooling tower with FRP material, multiple capacity options, CE certified. Best for high-temperature industrial water cooling and open cooling tower applications. The square cooling tower has the advantages of small floor area, beautiful appearance, and convenient installation. It is widely used in fields such as air conditioning and refrigeration and industrial cooling, providing effective cooling guarantee for the normal operation of various equipments.      

ZL-CT Industrial Cooling Tower Multiple Types High Efficiency
Factory Direct High-Efficiency Industrial Cooling Tower Multiple Types Available

Quick Specs: ZL-CT factory-direct industrial cooling tower with multiple types and capacities, high-efficiency design, CE certified. Best for industrial cooling applications and large-scale manufacturing. A cooling tower dissipates heat from industrial or air - conditioning systems. Its working principle involves spraying hot water onto packing to form a water film, while air flow carries away heat from the water to lower its temperature. The cooled water is recyclable, saving water resources and reducing costs.​ There are various types, such as open and closed cooling towers. Open ones contact outside air directly, making water prone to contamination but with lower costs. Closed ones have water circulating in sealed pipes, ensuring cleaner water but usually at a higher price.​ Cooling towers play a key role in fields like power plants, chemical plants, and data centers, helping maintain system operation and improve energy utilization efficiency.​  

Industrial FRP cooling tower at factory direct price for bulk procurement and wholesale orders with quality certification
10 Ton Industrial FRP Counter Flow Cooling Tower - CFO Procurement

Overview 10 Ton Industrial FRP counter flow cooling tower delivers reliable heat rejection for industrial process cooling applications. ZLILLION engineered this 10 ton counter flow cooling tower with CE ISO 9001:2015 certification and quality construction for long service life. Key Specifications Cooling capacity: 35.21 kW (10 refrigeration ton) Water flow rate: 7.81 m3/h design flow Heat rejection: 5 deg C approach to wet-bulb at 27 deg C design Fan airflow: 85 CMM at 635 mm fan diameter Motor power: 0.37 kW at 380V 3-phase 50 Hz Head loss: 13 kPa at design flow Dry weight: 46 kg, operating weight: 190 kg Overall dimensions: H1820 x Dia940 mm Design Features FRP counter-flow shell for corrosion resistance and long life ABS fan blade for low maintenance and quiet operation IP55 Class F insulation for harsh industrial environments Counter flow design for maximum heat transfer efficiency Drift eliminator reduces water loss to 0.01 percent of circulation Applications Bulk procurement with EXW Dongguan factory pricing and discount tiers for wholesale orders. T/T and L/C payment terms available for international buyers. Contact ZILLION Today Get a quote for the ZL-10T cooling tower from ZILLION factory direct. Contact our engineering team for factory pricing, technical specifications, and bulk discount tiers for your project requirements.

Low maintenance FRP cooling tower design with easy access for service technicians and weekly maintenance schedule
10 Ton Industrial FRP Counter Flow Cooling Tower - Maintenance Technician

Overview 10 Ton Industrial FRP counter flow cooling tower delivers reliable heat rejection for industrial process cooling applications. ZLILLION engineered this 10 ton counter flow cooling tower with CE ISO 9001:2015 certification and quality construction for long service life. Key Specifications Cooling capacity: 35.21 kW (10 refrigeration ton) Water flow rate: 7.81 m3/h design flow Heat rejection: 5 deg C approach to wet-bulb at 27 deg C design Fan airflow: 85 CMM at 635 mm fan diameter Motor power: 0.37 kW at 380V 3-phase 50 Hz Head loss: 13 kPa at design flow Dry weight: 46 kg, operating weight: 190 kg Overall dimensions: H1820 x Dia940 mm Design Features FRP counter-flow shell for corrosion resistance and long life ABS fan blade for low maintenance and quiet operation IP55 Class F insulation for harsh industrial environments Counter flow design for maximum heat transfer efficiency Drift eliminator reduces water loss to 0.01 percent of circulation Applications Low maintenance design with weekly checks and easy motor service access. Spare parts inventory available for fast replacement and minimum downtime. Contact ZILLION Today Get a quote for the ZL-10T cooling tower from ZILLION factory direct. Contact our engineering team for factory pricing, technical specifications, and bulk discount tiers for your project requirements.

380V 3-phase IP55 Class F cooling tower CE certified for HVAC EPC contractor projects and process cooling applications
10 Ton Industrial FRP Counter Flow Cooling Tower - HVAC EPC Contractor

Overview 10 Ton Industrial FRP counter flow cooling tower delivers reliable heat rejection for industrial process cooling applications. ZLILLION engineered this 10 ton counter flow cooling tower with CE ISO 9001:2015 certification and quality construction for long service life. Key Specifications Cooling capacity: 35.21 kW (10 refrigeration ton) Water flow rate: 7.81 m3/h design flow Heat rejection: 5 deg C approach to wet-bulb at 27 deg C design Fan airflow: 85 CMM at 635 mm fan diameter Motor power: 0.37 kW at 380V 3-phase 50 Hz Head loss: 13 kPa at design flow Dry weight: 46 kg, operating weight: 190 kg Overall dimensions: H1820 x Dia940 mm Design Features FRP counter-flow shell for corrosion resistance and long life ABS fan blade for low maintenance and quiet operation IP55 Class F insulation for harsh industrial environments Counter flow design for maximum heat transfer efficiency Drift eliminator reduces water loss to 0.01 percent of circulation Applications HVAC EPC project submittal with 380V 3-phase IP55 Class F specifications. Compatible with standard HVAC control systems and BMS integration. Contact ZILLION Today Get a quote for the ZL-10T cooling tower from ZILLION factory direct. Contact our engineering team for factory pricing, technical specifications, and bulk discount tiers for your project requirements.

If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

About Us

Whatsapp