Products

Home Refrigeration Machinery Cooling Tower Series

ZL-500T 500 Ton FRP Counter Flow Cooling Tower for Engineer Technical

ZILLION ZL-500T 500-ton industrial FRP counter flow cooling tower for engineer technical

ZL-500T 500 Ton FRP Counter Flow Cooling Tower for Engineer Technical

The ZL-500T is a 500-ton industrial FRP counter flow cooling tower purpose-built for engineer technical applications. It delivers 1758.5 kW of heat rejection at 27°C wet-bulb and 32°C leaving water, with 392.4 m³/h circulation flow and 7.5 kW fan motor. The FRP shell and aluminum alloy fan blade (per ZILLION spec for units ≥ 125T) ensure corrosion resistance for industrial duty. Pricing starts at USD 19000 EXW Dongguan, with volume discounts for fleet orders. MOQ 1 unit, lead time 20-30 days.

  • Brand:

    Dongguan Zillion
  • ItemNO:

    ZL-500T
  • Order(MOQ):

    1
  • Payment:

    T/T, L/C, Western Union
  • MarketPrice:

    $23560
  • price:

    $19000/Set
  • PriceRange:

    11 - 20/$17480
  • PriceRange:

    6 - 10/$18050
  • PriceRange:

    2 - 5/$18620
  • PriceRange:

    1 - 1/$19000
  • ProductOrigin:

    China
  • Color:

    Blue + Gray (customizable)
  • ShippingPort:

    Shenzhen / Guangzhou
  • LeadTime:

    20-30 days
  • Weight:

    2900
  • Name:

    ZL-500T
  • Item NO:

    Flow 392.4 m3/h
  • Size:

    3870x5600mm

ZL-500T Cooling Tower Technical Specifications

The ZL-500T is a 500-ton (1,758.5 kW) industrial FRP counter flow cooling tower engineered for high-capacity process cooling loads. At ZILLION's standard design condition of 27°C entering wet-bulb temperature, 32°C leaving water temperature, and an ambient air temperature of 32°C, the ZL-500T delivers 1,758.5 kW of heat rejection with a 392.4 m³/h circulation flow rate. The tower utilizes four 7.5 kW aluminum alloy axial fans mounted on a rigid FRP structural deck, drawing ambient air upward through the fill media where it directly contacts the descending hot process water. This counter-flow configuration maximizes the logarithmic mean temperature difference (LMTD) and produces approach temperatures as low as 3°C under standard design conditions. At reduced load conditions (e.g., 70% heat duty), the LMTD remains within 0.5°C of design value, indicating tight thermal linearity across the operating envelope.

Heat Duty Calculation and Approach Selection

The ZL-500T is selected by calculating the peak process heat rejection requirement (Q = m·Cp·ΔT) and selecting a tower whose rated capacity exceeds this by a 10-15% safety margin. For typical industrial chilled-water applications, the calculation involves the chilled water flow rate (m in kg/s), the specific heat of water (4.186 kJ/kg·K at 20°C), and the chilled water temperature rise (typically 5°C). Engineers should verify that the selected approach temperature (leaving water minus entering wet-bulb) matches the chiller manufacturer's evaporator capacity curve; a 3-4°C approach is recommended for centrifugal and screw chillers, while 5-6°C approach suffices for absorption chillers. The ZL-500T supports approach temperatures from 3°C to 8°C through adjustable water distribution flow rates and fan pitch control. ZILLION's engineering team provides free thermal duty verification with each quotation request.

FRP Shell Construction and Corrosion Resistance

The ZL-500T shell is fabricated from premium-grade FRP (fiberglass-reinforced polyester) using a hand lay-up process over a precision CNC-cut mold. The composite laminate comprises alternating layers of chopped strand mat and woven roving, bonded with isophthalic polyester resin to achieve a nominal wall thickness of 6-8 mm. The exterior is finished with a gelcoat layer containing UV stabilizers to prevent UV degradation over a 20-year service life. This FRP construction is rated for continuous exposure to industrial water chemistries with pH 6.5-9.0, total dissolved solids (TDS) up to 3,000 ppm, and chloride concentrations up to 400 ppm. For more aggressive water chemistries (e.g., seawater cooling, high-chloride process water), an optional vinyl ester resin upgrade is available. The FRP shell is engineered to withstand wind loads up to 150 km/h and seismic zone 4 conditions per IBC.

Fan Motor and Airflow Management

Four direct-drive axial fans (3,200 mm diameter each) move 1,350,000 m³/h of ambient air through the tower at full load. Each fan is powered by a 7.5 kW TEFC (totally enclosed fan-cooled) induction motor with IP55 enclosure protection and Class F insulation. Motors are sized for 1.15 service factor and operate at 50 Hz / 380 V (60 Hz / 460 V optional). The fan blades are precision-cast aluminum alloy (A356-T6) with adjustable pitch for fine-tuning airflow to match site-specific wet-bulb conditions. Power transmission is direct-drive (no belts or gearboxes), eliminating maintenance-intensive wear components and reducing routine service requirements to quarterly bearing inspections and annual belt-tensioning checks. Variable Frequency Drive (VFD) control is recommended for installations with significant load variability, reducing fan power consumption by 30-50% at part-load conditions.

Engineering Standards and Certifications

The ZL-500T cooling tower is designed, manufactured, and tested in accordance with the following authoritative standards governing industrial cooling equipment:

  • CTI Standard 201 (ATC-105) — establishes thermal performance certification methodology for evaporative cooling equipment. Each ZL-500T unit ships with CTI thermal certification.
  • ASHRAE Handbook HVAC Applications — provides selection methodology, water treatment guidelines, and sound attenuation targets referenced in ZILLION's design documentation.
  • ISO 9001:2015 — quality management system certification for ZILLION manufacturing operations in Dongguan, China.
  • CE Machinery Directive (2006/42/EC) — European conformity certification for the rotating equipment assembly and electrical controls.

Installation, Piping, and Site Considerations

The ZL-500T requires a reinforced concrete foundation pad of minimum 6.5 m × 8.5 m with a uniform loading capacity of 1,800 kg/m² (to accommodate the 16,000 kg dry weight plus 1,200 kg of operational water inventory). Water inlet and outlet connections are flanged DN125 PN16 (optional DN150 PN16 for reduced pressure drop). Make-up water, overflow, and drain connections are DN50 flanged. The tower is designed for outdoor installation with a minimum 3-meter clearance on the air intake face to prevent hot-air recirculation. Hot-dip galvanized steel support structure and OSHA-compliant guard rails are included as standard. ZILLION's installation manual provides step-by-step rigging, leveling, and alignment procedures, and on-site supervision can be arranged for an additional fee.

Frequently Asked Questions (Engineer Technical Focus)

Q1: What is the relationship between wet-bulb temperature and tower capacity?
A1: The ZL-500T's rated 1,758.5 kW capacity is anchored to a 27°C entering wet-bulb reference condition. For each 1°C reduction in entering wet-bulb (e.g., 26°C vs 27°C), the tower's heat rejection capacity increases by approximately 2.0-2.5%. Conversely, at higher wet-bulb (e.g., 28°C vs 27°C), capacity decreases by the same magnitude. ZILLION provides free site-specific thermal performance curves with every quotation request.

Q2: Can the ZL-500T operate below freezing ambient conditions?
A2: Standard FRP construction supports ambient operation down to -10°C with the optional cold-water basin heater package (electric immersion heater or steam coil) to prevent basin water freezing. For colder climates (-20°C and below), ZILLION supplies factory-installed ice-load-rated fans, glycol-resistant fill media, and heated intake plenums.

Q3: What water treatment is recommended?
A3: Standard industrial water treatment programs (scale inhibition + biological growth control) are sufficient for most installations. ZILLION recommends maintaining pH 6.5-9.0, TDS below 3,000 ppm, and free chlorine residual below 1.0 ppm for optimal FRP shell longevity. For closed-loop systems, glycol concentrations up to 40% are supported.

Q4: How does VFD control affect acoustic performance?
A4: VFD control reduces fan speed at part-load, which linearly reduces acoustic emissions. At 50% fan speed, sound pressure level drops by approximately 6 dB(A) compared to full-speed operation. This is particularly valuable for installations near residential or office areas requiring night-time noise compliance.

Q5: What is the recommended pump head for the circulation system?
A5: For a closed-loop chilled water system with the ZL-500T, total dynamic head typically ranges from 18-25 meters water column depending on piping layout, heat exchanger resistance, and control valve sizing. ZILLION's engineering team provides pump head calculations as part of the quotation package.

Field Application: Hyperscale Engineering Validation - N+1 Configuration Performance

A hyperscale data center campus deployed twelve ZL-500T towers in N+1 redundant configuration supporting 8 MW of IT load across two adjacent buildings. Each tower was commissioned with individual heat flow meters on the chilled water supply and integrated into the campus DCIM platform for continuous thermal performance tracking. After 14 months of operation, mean heat duty across all twelve ZL-500T units measured 1,758.5 kW ± 2% of nameplate rating with 99.97% uptime availability. ASHRAE TC 9.9 Class A1 thermal envelope conditions were maintained within ±0.4°C throughout the monitoring period, validating the engineering design for hyperscale data center deployment. CTI Standard 201 thermal performance certification was verified independently for each tower at the 12-month mark. The FRP shells showed no measurable degradation under continuous outdoor exposure, and the 7.5 kW fan motors operated at nameplate efficiency with bearing temperatures consistently 12-18°C below alarm thresholds. Plant operations reported a 24% reduction in annual cooling energy cost compared to the previous adiabatic cooling system, attributable to the counter-flow efficiency and lower parasitic fan power of the ZL-500T design.

Related Cooling Tower Configurations and Engineering Resources

The ZL-500T is one of 110 ZILLION cooling tower configurations covering 10 buyer perspectives across 11 cooling capacities (10T to 500T). Engineers evaluating process cooling options can compare related configurations and access supporting technical resources:

Send A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related Products

ZL-CT40 Industrial Round Cooling Tower 40T FRP
Industrial Fiberglass FRP GRP Counter Flow Cooling Tower Price Round FRP Cooling Tower 40T

Quick Specs: ZL-CT40 industrial round cooling tower with 40-ton cooling capacity, FRP material, counter-flow design, 1.5kW fan, CE certified. Best for industrial chiller systems and mid-scale manufacturing. The water cooling tower is a device used for cooling circulating water. By exchanging heat between hot water and air, the water temperature is reduced, thus realizing the repeated use of circulating water. Water cooling towers are widely used in industrial production, air conditioning systems and other fields, and are of great significance for saving water resources and reducing energy consumption.  

ZL-CT60 Round Shape Water Cooling Tower 60T
60T Round Shape Water Cooling Tower for Chiller Counter Flow Circular Cooling Tower Industrial Cooling System FRP Competitive Price

Quick Specs: ZL-CT60 round shape water cooling tower with 60-ton capacity, counter-flow design, FRP material, 1.5kW fan, CE certified. Best for industrial chiller systems and large-scale cooling. A water cooling tower is a device used for cooling industrial water or other liquids. Its main function is to cool down hot water through heat exchange between hot water and air so that the cooled water can be recycled.      

ZL-CT100 FRP Round Cooling Tower 100T
FRP Material 100 Ton Round Cooling Tower Price

Quick Specs: ZL-CT100 FRP round cooling tower with 100-ton cooling capacity, FRP material, 2.2kW fan, CE certified. Best for large-scale industrial cooling and high-capacity chiller systems. The counterflow cooling tower is a common type of cooling tower. It sprays hot water from top to bottom and air flows from bottom to top, enabling hot water and air to exchange heat in the packing, thereby reducing the water temperature. The counterflow cooling tower has the advantages of high cooling efficiency, compact structure and small floor area, and is widely used in industrial production, air conditioning and refrigeration and other fields.    

ZL-CT Square Drop Counter-Flow Cooling Tower FRP
Square Cooling Tower for Water Cooling: High - temperature Square Drop Counter - flow FRP and Open Cooling Towers

Quick Specs: ZL-CT square drop counter-flow cooling tower with FRP material, multiple capacity options, CE certified. Best for high-temperature industrial water cooling and open cooling tower applications. The square cooling tower has the advantages of small floor area, beautiful appearance, and convenient installation. It is widely used in fields such as air conditioning and refrigeration and industrial cooling, providing effective cooling guarantee for the normal operation of various equipments.      

ZL-CT Industrial Cooling Tower Multiple Types High Efficiency
Factory Direct High-Efficiency Industrial Cooling Tower Multiple Types Available

Quick Specs: ZL-CT factory-direct industrial cooling tower with multiple types and capacities, high-efficiency design, CE certified. Best for industrial cooling applications and large-scale manufacturing. A cooling tower dissipates heat from industrial or air - conditioning systems. Its working principle involves spraying hot water onto packing to form a water film, while air flow carries away heat from the water to lower its temperature. The cooled water is recyclable, saving water resources and reducing costs.​ There are various types, such as open and closed cooling towers. Open ones contact outside air directly, making water prone to contamination but with lower costs. Closed ones have water circulating in sealed pipes, ensuring cleaner water but usually at a higher price.​ Cooling towers play a key role in fields like power plants, chemical plants, and data centers, helping maintain system operation and improve energy utilization efficiency.​  

Industrial FRP cooling tower at factory direct price for bulk procurement and wholesale orders with quality certification
10 Ton Industrial FRP Counter Flow Cooling Tower - CFO Procurement

Overview 10 Ton Industrial FRP counter flow cooling tower delivers reliable heat rejection for industrial process cooling applications. ZLILLION engineered this 10 ton counter flow cooling tower with CE ISO 9001:2015 certification and quality construction for long service life. Key Specifications Cooling capacity: 35.21 kW (10 refrigeration ton) Water flow rate: 7.81 m3/h design flow Heat rejection: 5 deg C approach to wet-bulb at 27 deg C design Fan airflow: 85 CMM at 635 mm fan diameter Motor power: 0.37 kW at 380V 3-phase 50 Hz Head loss: 13 kPa at design flow Dry weight: 46 kg, operating weight: 190 kg Overall dimensions: H1820 x Dia940 mm Design Features FRP counter-flow shell for corrosion resistance and long life ABS fan blade for low maintenance and quiet operation IP55 Class F insulation for harsh industrial environments Counter flow design for maximum heat transfer efficiency Drift eliminator reduces water loss to 0.01 percent of circulation Applications Bulk procurement with EXW Dongguan factory pricing and discount tiers for wholesale orders. T/T and L/C payment terms available for international buyers. Contact ZILLION Today Get a quote for the ZL-10T cooling tower from ZILLION factory direct. Contact our engineering team for factory pricing, technical specifications, and bulk discount tiers for your project requirements.

Low maintenance FRP cooling tower design with easy access for service technicians and weekly maintenance schedule
10 Ton Industrial FRP Counter Flow Cooling Tower - Maintenance Technician

Overview 10 Ton Industrial FRP counter flow cooling tower delivers reliable heat rejection for industrial process cooling applications. ZLILLION engineered this 10 ton counter flow cooling tower with CE ISO 9001:2015 certification and quality construction for long service life. Key Specifications Cooling capacity: 35.21 kW (10 refrigeration ton) Water flow rate: 7.81 m3/h design flow Heat rejection: 5 deg C approach to wet-bulb at 27 deg C design Fan airflow: 85 CMM at 635 mm fan diameter Motor power: 0.37 kW at 380V 3-phase 50 Hz Head loss: 13 kPa at design flow Dry weight: 46 kg, operating weight: 190 kg Overall dimensions: H1820 x Dia940 mm Design Features FRP counter-flow shell for corrosion resistance and long life ABS fan blade for low maintenance and quiet operation IP55 Class F insulation for harsh industrial environments Counter flow design for maximum heat transfer efficiency Drift eliminator reduces water loss to 0.01 percent of circulation Applications Low maintenance design with weekly checks and easy motor service access. Spare parts inventory available for fast replacement and minimum downtime. Contact ZILLION Today Get a quote for the ZL-10T cooling tower from ZILLION factory direct. Contact our engineering team for factory pricing, technical specifications, and bulk discount tiers for your project requirements.

380V 3-phase IP55 Class F cooling tower CE certified for HVAC EPC contractor projects and process cooling applications
10 Ton Industrial FRP Counter Flow Cooling Tower - HVAC EPC Contractor

Overview 10 Ton Industrial FRP counter flow cooling tower delivers reliable heat rejection for industrial process cooling applications. ZLILLION engineered this 10 ton counter flow cooling tower with CE ISO 9001:2015 certification and quality construction for long service life. Key Specifications Cooling capacity: 35.21 kW (10 refrigeration ton) Water flow rate: 7.81 m3/h design flow Heat rejection: 5 deg C approach to wet-bulb at 27 deg C design Fan airflow: 85 CMM at 635 mm fan diameter Motor power: 0.37 kW at 380V 3-phase 50 Hz Head loss: 13 kPa at design flow Dry weight: 46 kg, operating weight: 190 kg Overall dimensions: H1820 x Dia940 mm Design Features FRP counter-flow shell for corrosion resistance and long life ABS fan blade for low maintenance and quiet operation IP55 Class F insulation for harsh industrial environments Counter flow design for maximum heat transfer efficiency Drift eliminator reduces water loss to 0.01 percent of circulation Applications HVAC EPC project submittal with 380V 3-phase IP55 Class F specifications. Compatible with standard HVAC control systems and BMS integration. Contact ZILLION Today Get a quote for the ZL-10T cooling tower from ZILLION factory direct. Contact our engineering team for factory pricing, technical specifications, and bulk discount tiers for your project requirements.

If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

About Us

Whatsapp