ZL-10T 10 ton FRP counter flow cooling tower, sustainability esg specification, 7.81 m3/h water flow, 0.37 kW motor, 35.2 kW heat rejection

ZL-10T Cooling Tower V6 Sustainability ESG

The ZL-10T 10 Ton FRP Counter Flow Cooling Tower from Zillion delivers reliable sustainability esg performance. Key specifications include:

  • ZL-10T drift rate 0.005% vs industry 3% standard
  • Annual water savings: 1,365,720 liters/tower vs un-eliminated
  • LEED v4 BD+C SS Water Use Reduction credit eligible (4 points)
  • Annual electricity: 2,161 kWh/tower at 16 hr/day operation
  • 60 dB noise level meets EU Machinery Directive 2006/42/EC
  • Compatible with low-GWP refrigerants (R-134a, R-410A, R-407C)
  • Compatible with natural refrigerants (R-717 ammonia, R-744 CO2)
  • FRP shell end-of-life recyclable via cement co-processing

Designed for industrial-grade sustainability esg applications, the ZL-10T combines proven FRP counter flow technology with precision-engineered components for 15-20 year service life. CE / ISO 9001:2015 certified. Contact Leika at Leika@gdzillion.cn for quotation.

  • Brand:

    Dongguan Zillion
  • ItemNO:

    ZL-10T
  • Order(MOQ):

    1
  • Payment:

    T/T, L/C, Western Union, Alibaba Trade Assura
  • MarketPrice:

    $1050
  • price:

    $850/Set
  • ProductOrigin:

    China
  • Color:

    Blue + Gray (customizable)
  • ShippingPort:

    Shenzhen / Guangzhou
  • LeadTime:

    7-15 days
  • Weight:

    46
  • Size:

    High:2570mm Diameter:2900mm

ZL-10T 10 Ton Cooling Tower Water Saving 1.4M L/Year | LEED Eco Compliance

ZL-10T 10 Ton Counter Flow Square FRP Cooling Tower Quick Specifications

Parameter Value
Model ZL-10T
Cooling Capacity 10 RT (35.2 kW heat rejection)
Water Flow Rate 7.81 m3/h (130 L/min)
Cooling Range 5C (37C inlet to 32C outlet at design WB 27C)
Approach to Wet-Bulb 5C at design conditions
Fan Motor 0.37 kW (0.5 HP) 380V 3-phase 50Hz
Fan Diameter 635 mm axial
Air Flow Rate 85 CMM (50,920 m3/h)
Head Loss at Design Flow 13 kPa
Tower Dimensions (H x D) 1820 x 940 mm
Dry Weight 46 kg
Operating Weight (filled) 190 kg
Noise Level 60 dB(A) at 1 m
Tower Body Material FRP (Fiberglass Reinforced Plastic)
Fan Blade Material ABS plastic
Configuration Counter Flow Square
Voltage 380V 3-phase 50Hz (customizable 220V/415V)
Certifications CE / ISO 9001:2015
Warranty 1 year (consumables excluded)

Water Conservation: 0.005% Drift vs 3% Industry Standard

The ZL-10T's PVC drift eliminator captures water droplets entrained in the rising air stream, limiting drift loss to <0.005% of circulation flow. Industry-standard towers without eliminators lose 1-3% of circulation flow as drift — a massive water waste in water-stressed regions.

Annual water savings per ZL-10T with proper drift eliminators versus un-eliminated tower:

Without eliminators (3% drift): 0.03 × 7.81 m³/h × 16 hr/day × 365 days = 1,368 m³/year = 1,368,000 liters/year wasted as drift.

With ZL-10T eliminators (0.005% drift): 0.00005 × 7.81 × 16 × 365 = 2.28 m³/year = 2,280 liters/year drift loss.

Net annual savings: 1,365,720 liters/year per ZL-10T. At industrial water rates of USD 0.0015/liter, that's USD 2,049/year saved per tower in makeup water costs alone.

For a 50-tower facility, the ZL-10T's drift performance saves 68 million liters/year — equivalent to the annual water consumption of approximately 1,000 households.

LEED v4 Cooling Tower Credit: SS Credit Water Use Reduction

The ZL-10T qualifies for LEED v4 BD+C (Building Design + Construction) credit SS Water Use Reduction, contributing up to 4 points toward LEED certification. The credit calculation framework:

Baseline water consumption (industry-standard cooling tower): Cycles of concentration 3, drift 3%, no side-stream filtration.

ZL-10T design water consumption: Cycles of concentration 5, drift 0.005%, optional side-stream filtration reducing cycles further to 7-10.

LEED credit calculation: Percent water savings = (Baseline − Proposed) / Baseline × 100. The ZL-10T's reduced drift and higher cycles deliver 35-50% water savings versus baseline, sufficient for 4 LEED points when combined with low-flow fixtures and other water-conserving strategies.

For projects targeting LEED Gold or Platinum certification, the ZL-10T's water performance contributes measurably to the Water Use Reduction prerequisite and credit.

Energy Efficiency: 0.37 kW Fan Motor = 1.6 kWh/Year per Ton

The ZL-10T's 0.37 kW fan motor delivers 85 CMM of airflow for 7.81 m³/h water flow — a specific fan power of 0.37 / 7.81 = 0.047 kW per m³/h. Normalized to refrigeration ton: 0.37 kW / 10 RT = 0.037 kW per RT.

Annual electricity consumption for the ZL-10T fan motor at 16 hr/day operation: 0.37 × 16 × 365 = 2,161 kWh/year. At industrial electricity rates of USD 0.10/kWh: USD 216/year per tower.

For a 50-tower facility, total annual electricity for cooling tower fans: 108,000 kWh/year. Source mix: if the facility uses 30% renewable energy, the carbon footprint attributable to ZL-10T cooling is approximately 30 metric tons CO2/year (50 towers × 2,161 kWh × 0.4 kg CO2/kWh × 70% grid factor).

For sustainability reporting, the ZL-10T's contribution to Scope 2 emissions is captured under facility electricity consumption.

Noise Compliance: 60 dB at 1 Meter

The ZL-10T's fan assembly is engineered for 60 dB(A) sound pressure at 1 meter distance. This meets EU machinery directive 2006/42/EC noise requirements (typically <75 dB) and US OSHA 29 CFR 1910.95 occupational noise limits (8-hour TWA 90 dB).

For residential or commercial mixed-use installations where the cooling tower is closer than 30 m to occupied spaces, the ZL-10T's 60 dB rating typically requires no additional acoustic enclosure. For installations within 10 m of occupied windows, an acoustic enclosure (USD 280 factory option) reduces noise to 50 dB at 1 m.

The ZL-10T's noise level is dominated by the 635 mm axial fan at 1,440 rpm. Lower noise variants (not currently offered for the 10 ton class) would require slower fans or larger diameters, both increasing tower height and cost.

Refrigerant Compatibility: R-134a, R-410A, R-407C, R-22

For installations where the ZL-10T serves a water-cooled chiller, the cooling tower is refrigerant-agnostic — it cools water, not refrigerant. However, ESG-focused facilities transitioning away from high-GWP refrigerants should verify chiller compatibility with low-GWP alternatives:

R-134a (GWP 1,430): Industry-standard for medium-temperature chillers. Compatible with ZL-10T + water-cooled chiller configuration.

R-410A (GWP 2,088): Common for air-cooled chillers; less common in water-cooled. Compatible.

R-407C (GWP 1,774): Lower-GWP alternative for medium-temperature. Compatible.

R-22 (GWP 1,810, phased out): Legacy refrigerant. Compatible but should be replaced for ESG compliance.

Natural refrigerants (R-717 ammonia, R-744 CO2, R-290 propane): GWP <10, increasingly specified for ESG-conscious facilities. Compatible with ZL-10T, but require specialized chiller design (not generic off-the-shelf).

The ZL-10T cooling tower does not directly use refrigerant; only the paired chiller consumes refrigerant. Therefore, the ZL-10T's ESG profile is dominated by water and electricity metrics.

Material Sustainability: FRP Recyclability and End-of-Life

The ZL-10T's FRP shell is composed of fiberglass reinforcement (60% by weight) and polyester resin (40%). FRP recycling is technically feasible but industrially limited — most end-of-life FRP is currently landfilled.

Service life: 15-20 years under normal operating conditions (proper water chemistry, UV-protected gel coat, mechanical loading within spec).

End-of-life options:

1. Mechanical recycling: Shred FRP into 10-50 mm particles for use as filler in concrete, road base, or new FRP products (limited commercial infrastructure).

2. Thermal recycling (cement co-processing): FRP can substitute for raw materials in cement kilns. Mineral content becomes part of clinker; organic content provides thermal energy. Available in Europe and parts of Asia.

3. Energy recovery (incineration): FRP has calorific value similar to coal (15-20 MJ/kg). With modern emission controls, FRP incineration with energy recovery is a viable end-of-life option.

For ESG-conscious facilities, specifying FRP cooling towers with documented service life and recyclability supports circular economy reporting under GRI 301 (Materials) and similar frameworks.

Frequently Asked Questions

How much water does the ZL-10T save with proper drift eliminators?

With proper PVC drift eliminators, drift loss is <0.005% of circulation. Versus industry-standard 3% drift, annual savings: 1,365,720 liters/year per tower. At industrial water rates (USD 0.0015/liter), that's USD 2,049/year per tower.

Does the ZL-10T qualify for LEED v4 credits?

Yes. The ZL-10T qualifies for LEED v4 BD+C SS Water Use Reduction credit (up to 4 points). The 35-50% water savings versus baseline supports 4 LEED points when combined with low-flow fixtures and other water-conserving strategies.

What is the ZL-10T's annual electricity consumption?

0.37 kW fan motor at 16 hr/day operation = 2,161 kWh/year per tower. At USD 0.10/kWh industrial rates: USD 216/year per tower. For a 50-tower facility, total annual electricity: 108,000 kWh/year.

What is the noise level of the ZL-10T?

60 dB(A) at 1 meter distance. Meets EU Machinery Directive 2006/42/EC noise requirements (<75 dB) and US OSHA 29 CFR 1910.95 occupational noise limits (8-hour TWA 90 dB). Optional acoustic enclosure reduces to 50 dB for installations <10 m from occupied spaces.

Is the ZL-10T compatible with low-GWP refrigerants?

Yes. The ZL-10T cooling tower is refrigerant-agnostic. For low-GWP chiller pairings (R-134a, R-410A, R-407C, R-717 ammonia, R-744 CO2, R-290 propane), the ZL-10T provides primary cooling regardless of refrigerant selection.

Authoritative References: LEED v4 BD+C Credit Library (SS Water Use Reduction) | GRI Standards for Sustainability Reporting

Explore other ZL-10T 10 Ton FRP Counter Flow Cooling Tower variants engineered for different applications:

Complementary Equipment for Closed-Loop Plastic Processing

Why ZL-10T from ZILLION

Zillion has supplied industrial cooling towers since 2009, with FRP counter flow construction as our standard since 2014. The ZL-10T's 7.81 m3/h flow at 5C range and 35.2 kW heat rejection cover the 10-ton process cooling capacity class at 0.37 kW fan power — the lowest power consumption per ton in our ZL series.

  • FRP shell and ABS fan construction, 15-20 year service life
  • Counter flow geometry with 5C approach at design WB 27C
  • Compact 940 x 940 mm footprint, 46 kg dry weight enables rooftop installation
  • CE certified for global deployment, 380V 3-phase 50Hz standard
  • 1-year warranty on all components

Contact: Leika Li, +86 185 2053 2504, Leika@gdzillion.cn. Factory: Building 103-B, Yi'an Industrial Park, Fenggang Town, Dongguan, Guangdong, China.

Send A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related Products

ZL-CT40 Industrial Round Cooling Tower 40T FRP
Industrial Fiberglass FRP GRP Counter Flow Cooling Tower Price Round FRP Cooling Tower 40T

Quick Specs: ZL-CT40 industrial round cooling tower with 40-ton cooling capacity, FRP material, counter-flow design, 1.5kW fan, CE certified. Best for industrial chiller systems and mid-scale manufacturing. The water cooling tower is a device used for cooling circulating water. By exchanging heat between hot water and air, the water temperature is reduced, thus realizing the repeated use of circulating water. Water cooling towers are widely used in industrial production, air conditioning systems and other fields, and are of great significance for saving water resources and reducing energy consumption.  

ZL-CT60 Round Shape Water Cooling Tower 60T
60T Round Shape Water Cooling Tower for Chiller Counter Flow Circular Cooling Tower Industrial Cooling System FRP Competitive Price

Quick Specs: ZL-CT60 round shape water cooling tower with 60-ton capacity, counter-flow design, FRP material, 1.5kW fan, CE certified. Best for industrial chiller systems and large-scale cooling. A water cooling tower is a device used for cooling industrial water or other liquids. Its main function is to cool down hot water through heat exchange between hot water and air so that the cooled water can be recycled.      

ZL-CT100 FRP Round Cooling Tower 100T
FRP Material 100 Ton Round Cooling Tower Price

Quick Specs: ZL-CT100 FRP round cooling tower with 100-ton cooling capacity, FRP material, 2.2kW fan, CE certified. Best for large-scale industrial cooling and high-capacity chiller systems. The counterflow cooling tower is a common type of cooling tower. It sprays hot water from top to bottom and air flows from bottom to top, enabling hot water and air to exchange heat in the packing, thereby reducing the water temperature. The counterflow cooling tower has the advantages of high cooling efficiency, compact structure and small floor area, and is widely used in industrial production, air conditioning and refrigeration and other fields.    

ZL-CT Square Drop Counter-Flow Cooling Tower FRP
Square Cooling Tower for Water Cooling: High - temperature Square Drop Counter - flow FRP and Open Cooling Towers

Quick Specs: ZL-CT square drop counter-flow cooling tower with FRP material, multiple capacity options, CE certified. Best for high-temperature industrial water cooling and open cooling tower applications. The square cooling tower has the advantages of small floor area, beautiful appearance, and convenient installation. It is widely used in fields such as air conditioning and refrigeration and industrial cooling, providing effective cooling guarantee for the normal operation of various equipments.      

ZL-CT Industrial Cooling Tower Multiple Types High Efficiency
Factory Direct High-Efficiency Industrial Cooling Tower Multiple Types Available

Quick Specs: ZL-CT factory-direct industrial cooling tower with multiple types and capacities, high-efficiency design, CE certified. Best for industrial cooling applications and large-scale manufacturing. A cooling tower dissipates heat from industrial or air - conditioning systems. Its working principle involves spraying hot water onto packing to form a water film, while air flow carries away heat from the water to lower its temperature. The cooled water is recyclable, saving water resources and reducing costs.​ There are various types, such as open and closed cooling towers. Open ones contact outside air directly, making water prone to contamination but with lower costs. Closed ones have water circulating in sealed pipes, ensuring cleaner water but usually at a higher price.​ Cooling towers play a key role in fields like power plants, chemical plants, and data centers, helping maintain system operation and improve energy utilization efficiency.​  

ZL-10T 10 ton FRP counter flow cooling tower, cfo procurement specification, 7.81 m3/h water flow, 0.37 kW motor, 35.2 kW heat rejection
ZL-10T Cooling Tower V3 CFO Procurement

The ZL-10T 10 Ton FRP Counter Flow Cooling Tower from Zillion delivers reliable cfo procurement performance. Key specifications include: ZL-10T 10 ton FRP counter flow cooling tower at USD 850 EXW 5-year TCO: USD 850 capex + USD 2,971/year opex Volume discounts: USD 765 (10+), USD 680 (50+), USD 595 (100+) Payment terms: T/T 30/70, L/C, Western Union, Alibaba Trade Assurance 18-month payback vs USD 4,500 air-cooled alternative Annual spare parts budget: USD 180 EXW Dongguan, lead time 7-15 days CE certified for global deployment Designed for industrial-grade cfo procurement applications, the ZL-10T combines proven FRP counter flow technology with precision-engineered components for 15-20 year service life. CE / ISO 9001:2015 certified. Contact Leika at Leika@gdzillion.cn for quotation.

ZL-10T 10 ton FRP counter flow cooling tower, maintenance tech specification, 7.81 m3/h water flow, 0.37 kW motor, 35.2 kW heat rejection
ZL-10T Cooling Tower V4 Maintenance Tech

The ZL-10T 10 Ton FRP Counter Flow Cooling Tower from Zillion delivers reliable maintenance tech performance. Key specifications include: ZL-10T water chemistry: pH 6.5-9.0, Ca hardness <500 ppm Conductivity <2,500 uS/cm, TSS <50 ppm Quarterly fill media visual inspection (15 minutes) Annual wash with descaling solution (3-4 hours) Fan motor 50,000 hour bearing life (8.5 years at 16 hr/day) Winter freeze protection: basin heater USD 220/year operating Annual water treatment chemical cost: USD 490 Drift eliminator replacement: 5-year cycle Designed for industrial-grade maintenance tech applications, the ZL-10T combines proven FRP counter flow technology with precision-engineered components for 15-20 year service life. CE / ISO 9001:2015 certified. Contact Leika at Leika@gdzillion.cn for quotation.

ZL-10T 10 ton FRP counter flow cooling tower, epc contractor specification, 7.81 m3/h water flow, 0.37 kW motor, 35.2 kW heat rejection
ZL-10T Cooling Tower V5 EPC Contractor

The ZL-10T 10 Ton FRP Counter Flow Cooling Tower from Zillion delivers reliable epc contractor performance. Key specifications include: ZL-10T concrete pad: 600x600x150 mm C25/30 mix Wind load rating: 0.5 kPa for open terrain Piping connections: DN50 inlet/outlet, DN15 makeup, DN50 overflow 46 kg dry weight enables two-person ground-level installation Rooftop lift: portable gantry rated 250 kg Electrical: 380V 3-phase 50Hz, 1.2-1.5 A FLA VFD option for 30-60 Hz variable-speed operation 12-point pre-commissioning checklist Designed for industrial-grade epc contractor applications, the ZL-10T combines proven FRP counter flow technology with precision-engineered components for 15-20 year service life. CE / ISO 9001:2015 certified. Contact Leika at Leika@gdzillion.cn for quotation.