ZL-200T 200 Ton FRP Counter Flow Cooling Tower for Maintenance Technician
The ZL-200T cooling tower is designed, manufactured, and tested in accordance with the following authoritative standards supporting Maintenance Technician applications:
The ZL-200T is one of 10 active ZL-200T configurations covering Maintenance Technician applications plus 10 buyer perspectives across 11 cooling capacities (10T to 500T). Engineers evaluating cooling options can compare related configurations:
| Parameter | Value |
|---|---|
| Model | ZL-200T |
| Cooling Capacity | 200 RT (703.4 kW heat rejection) |
| Water Flow Rate | 156.2 m3/h (2603 L/min) |
| Cooling Range | 5C (37C inlet to 32C outlet at design WB 27C) |
| Approach to Wet-Bulb | 5C at design conditions |
| Fan Motor | 4 kW (5.36 HP) 380V 3-phase 50Hz |
| Fan Diameter | 1750 mm axial |
| Air Flow Rate | 1250 CMM (750000 m3/h) |
| Head Loss at Design Flow | 30 kPa |
| Tower Dimensions (H x D) | 2850 x 3300 mm |
| Dry Weight | 880 kg |
| Operating Weight (filled) | 1980 kg |
| Noise Level | 68 dB(A) at 1 m |
| Tower Body Material | FRP (Fiberglass Reinforced Plastic) |
| Fan Blade Material | Aluminum alloy |
| Configuration | Counter Flow Square |
| Voltage | 380V 3-phase 50Hz (customizable 220V/415V) |
| Certifications | CE / ISO 9001:2015 |
| Warranty | 1 year (consumables excluded) |
Routine maintenance schedule: weekly water level check, monthly water quality test, quarterly fill inspection, annual full shutdown inspection
Water treatment protocol with NSF/ANSI 60 certified scale inhibitor, corrosion inhibitor, and oxidizing biocide maintains 800-2500 µS/cm conductivity
Spare parts kit with SKF bearings, V-belts, spray nozzles, float valve, and basin chemicals provides 24-hour delivery to most industrial zones
Vibration analysis per ISO 10816-3 with handheld analyzer at fan motor bearing housings identifies Zone C/D conditions requiring maintenance
Cold climate package with thermostat-controlled fan, basin heater, and recirculation bypass enables sub-freezing operation below 0C ambient
Maintenance technician training with 3-day on-site program and multilingual materials (English/Spanish/Mandarin/Arabic) for global workforce
Standard water treatment for closed-loop industrial cooling includes scale inhibitor (polyphosphate-based, 2-5 ppm), corrosion inhibitor (molybdate-based, 50-100 ppm), and biological growth control (oxidizing biocide, 0.5-1.0 ppm free chlorine residual). Conductivity maintained at 800-2500 µS/cm with pH 7.5-9.0. ZILLION provides water treatment calculator based on local makeup water analysis.
Fill media inspection recommended every 6 months for visual scaling, biological fouling, and mechanical damage assessment. PVC fill typically requires replacement at 7-10 year intervals depending on water quality. ZILLION provides annual fill condition scoring service with photo documentation and replacement recommendations based on thermal performance trend analysis.
Critical spare parts inventory recommended: 2x fan motor bearings (SKF 6309-2RS1), 1x V-belt set (matched pair), 1x spray nozzle set (6 nozzles), 1x float valve assembly, 1x eliminator section (1 meter length), 5x basin water treatment chemicals. ZILLION ships spare parts kits with 24-hour delivery to most industrial zones in Southeast Asia and Middle East.
Vibration analysis baseline measurements taken at fan motor bearing housings (horizontal/vertical/axial) using handheld analyzer. ISO 10816-3 severity zones: Zone A (less than 2.8 mm/s) Good, Zone B (2.8-4.5 mm/s) Acceptable, Zone C (4.5-7.1 mm/s) Requires maintenance, Zone D (greater than 7.1 mm/s) Immediate shutdown. Common faults: bearing wear, impeller balance, foundation looseness.
Cold climate operation below 0C requires: (1) installation of thermostat-controlled fan motor to slow airflow at low load, (2) basin heater sized at 0.5 kW per ton for sub-freezing ambient, (3) water flow reduction to 50 percent of design at temperatures below -10C, (4) internal recirculation bypass for freeze protection. ZILLION provides cold climate package factory-installed.
A 12-tower cooling system at a Middle East petrochemical complex uses ZL-200T as the standard platform with maintenance technician team managing predictive maintenance via vibration analysis. Weekly vibration readings collected at 36 measurement points across 12 towers, with ISO 10816-3 severity zone trending identifying 2 motors requiring bearing replacement before failure. Annual water treatment analysis showed 92 percent tower availability versus industry benchmark 78 percent. Maintenance technician standardized spare parts kit with SKF bearings, V-belts, and fill sections reduced mean time to repair (MTTR) from 8 hours to 2.5 hours.
ZL-200T meets ASHRAE 188 Legionellosis: Risk Management for Building Water Systems standard with documented water management plan, temperature monitoring, biocide treatment program, and quarterly water testing for Legionella. Basin temperature maintained above 25C or below 20C to prevent Legionella growth range. Quarterly water test reports provided.
ZL-200T routine maintenance does not require special occupational health monitoring beyond standard hearing protection during fan motor service. Quarterly water testing for Legionella per ASHRAE 188 supports worker health surveillance. Confined space entry into basin requires per OSHA 1910.146 with retrieval system and atmospheric monitoring.
ZL-200T water treatment chemicals include: scale inhibitor (polyphosphate, NSF/ANSI 60 certified), corrosion inhibitor (molybdate, NSF/ANSI 60 certified), oxidizing biocide (chlorine or bromine, NSF/ANSI 60 certified). All chemicals with Safety Data Sheets per OSHA HazCom 2012 (GHS). Chemical inventory per EPA Tier II reporting where applicable.
ZL-200T end-of-life recycling program recovers 85 percent of mass through FRP cement kiln co-processing, PVC mechanical recycling, and stainless steel scrap recovery. Component-level material passports per ISO 18813 provided for circular economy tracking. Annual recycling rate disclosure per GRI 301 Materials standard.
ZILLION standard 3-day maintenance technician training covers preventive maintenance procedures, water treatment chemistry, fan motor service, and troubleshooting. Multilingual training materials and annual refresher certification included. Advanced 5-day certification program for mission-critical facilities available at additional cost.
ZL-200T safety features including emergency stop, vibration alarm, and confined space provisions support plant safety incentive programs. Lock-out tag-out compliance with OSHA 1910.147 documented for energy isolation procedures. Annual safety audit support and root cause analysis templates provided for maintenance incident investigation.
ZILLION is a global leader in industrial FRP counter flow cooling tower manufacturing with 10+ years of proven track record across 47 countries. For Maintenance Technician buyers evaluating cooling equipment suppliers, ZILLION delivers distinct advantages:
Contact ZILLION for ZL-200T quotation, technical submittal package, and reference customer contacts in your industry:
Leika Li Tel / WhatsApp: +86 185 2053 2504 | Email: leika@gdzillion.cn
Hendrix Lee Tel / WhatsApp: +86 156 0223 2700 | Email: hendrix@gdzillion.cn
Address: No. 2 (103B), Yian Industrial Zone, Fenggang Town, Dongguan City, Guangdong Province, China
Online Inquiry: https://zillionchiller.com/contact-us_d2
The ZL-200T 200-ton counter flow cooling tower is available in 10 perspective-specific configurations covering different buyer priorities. Each variant emphasizes different technical specifications, applications, and operational considerations while maintaining the same thermal performance baseline. Buyers can compare all ZL-200T variants:
ZILLION manufactures a complete range of industrial process cooling equipment for plastics processing, HVAC, data center, pharmaceutical, and food processing applications. Buyers specifying the ZL-200T cooling tower often pair it with complementary ZILLION products:
Buyers evaluating the ZL-200T cooling tower can reference ZL-CT cooling tower product variants, ZILLION cooling tower industry articles, and complementary ZILLION industrial equipment resources. The ZL-CT series includes square counter flow, round counter flow, and 60T to 500T capacities for industrial process cooling applications: